Back to top
Human Body Static Discharge Pole DP 02
Human Body Static Discharge Pole DP 02
Human Body Static Discharge Pole DP 02
Human Body Static Discharge Pole DP 02
Human Body Static Discharge Pole DP 02
Human Body Static Discharge Pole DP 02
Human Body Static Discharge Pole DP 02
Human Body Static Discharge Pole DP 02

Human Body Static Discharge Pole DP 02

Price 15499 INR/ Piece

MOQ : 1 Piece

Human Body Static Discharge Pole DP 02 Specification

  • Product Type
  • Static Discharge Pole
  • Material
  • Stainless Steel Body with Insulated Handle
  • Application
  • Discharging Static Electricity from Human Body before Entering Sensitive ESD Areas
  • Surface Resistance
  • 10^6 - 10^9 Ohms
  • Usage
  • Touch to Discharge Static
  • Testing Function
  • Visual Indication by LED
  • Trigger Mode
  • Manual Touch
  • Size
  • Standard Length approx. 1200 mm
  • Color
  • Grey and Blue
 

Human Body Static Discharge Pole DP 02 Trade Information

  • Minimum Order Quantity
  • 1 Piece
  • Payment Terms
  • Telegraphic Transfer (T/T), Cash in Advance (CID)
  • Delivery Time
  • 1 Days
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Domestic Market
  • All India
 

About Human Body Static Discharge Pole DP 02

Reliable Static Discharge Protection
The DP 02 pole is designed to safely discharge static buildup from the human body, helping prevent electrostatic damage in ESD-sensitive areas. The robust stainless-steel construction and powder-coated finish offer enhanced durability, making it suitable for high-traffic environments such as manufacturing, assembly, or laboratory settings.

User-Friendly Operation

With its intuitive manual touch trigger and insulated handle, the pole provides hassle-free usage. The LED visual indicator makes the discharge process transparent to users and supervisors, ensuring static removal is achieved before personnel progress into protected zones.

Environmental and Compliance Assurance

Engineered to perform in conditions from 0C to 50C and up to 85% relative humidity, the DP 02 maintains strict RoHS compliance. Its efficient grounding and reliable surface resistance standards contribute to safe, environmentally responsible ESD management.

 

 

Measurement Range 0 to 1000 V
Display Type Analog
Power Source AAA Battery
Model Name/Number ARO-DP02
Usage/Application STATIC DISCHARGE
Unit Size Hight 1000mm
Averages 90 Days
Power Supply 3.6V
Feature Used in EPA (ESD protected area), Paint manufacturing Industries, gas station unloading port, self-s
Max Test voltage 3.6V
Brand ARO

FAQ's of Human Body Static Discharge Pole DP 02:


Q: How do you use the DP 02 Static Discharge Pole to remove static electricity?

A: To operate the DP 02, simply touch the insulated handle of the pole before entering an ESD-sensitive zone. The manual touch trigger activates the discharge process through a contact-based detection system, confirmed by the LED visual indicator.

Q: What is the benefit of using the LED visual indicator on the DP 02 pole?

A: The LED visual indicator offers instant feedback, assuring users that static discharge has occurred and the pole is functioning properly. This visual confirmation enhances safety compliance and operational reliability.

Q: Where is the DP 02 Static Discharge Pole typically installed or mounted?

A: The pole is floor-standing and designed to be installed at entrances to controlled ESD environments, such as electronics manufacturing, testing facilities, or cleanrooms, ensuring personnel discharge static before entering.

Q: What materials and finish ensure the durability of the DP 02 pole?

A: Constructed from stainless steel with a resilient powder-coated finish, the pole is built to withstand frequent use and harsh environments while maintaining its performance and appearance.

Q: When should the static discharge pole be used during facility operations?

A: Personnel should use the DP 02 static discharge pole every time before entering areas where sensitive electronic components are handled, to minimize the risk of electrostatic damage.

Q: What environmental conditions can the DP 02 operate in?

A: The pole is effective in temperatures from 0C to 50C and relative humidity up to 85%, making it suitable for a wide range of workplace environments.

Q: What process is followed for testing the discharge functionality of the DP 02 pole?

A: The pole utilizes a visual indication system; upon manual contact, the built-in LED lights up to confirm successful discharge and proper pole operation.

Technical Details 

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in ESD Products Category

ESD Dotted Gloves

ESD Dotted Gloves

Price 19 INR / Pair

Minimum Order Quantity : 1 Pair

Color : white

Size : Standard

Application : NA

Surface Resistance : NA

PU FINGER TIP COATED GLOVES

PU FINGER TIP COATED GLOVES

Price 26 INR / Pair

Minimum Order Quantity : 10 Pairs

Color : Grey

Size : Standard

Application : gloves

Surface Resistance : Smooth

ESD Antistatic Footwear

ESD Antistatic Footwear

Price 350 INR / Pair

Minimum Order Quantity : 1 Pair

Color : Black

Size : 6

Application : Industrial

Surface Resistance : Smooth

ESD BRUSHES

ESD BRUSHES

Price 25 INR / Piece

Minimum Order Quantity : 1 , , Piece

Color : Black

Size : Standard

Surface Resistance : Smooth